Cisco Nexus 93180YC-FX3 ACI-Mode Switch Hardware Installation Guide - Overview [Cisco Nexus 9000 Series Switches] (2024)

The Cisco Nexus 93180YC-FX3 switch (N9K-C93180YC-FX3, N9K-C93180YC-FX3H) is a 1-rack unit (RU), fixed-port switch designed for spine-leaf-APIC deployment in data centers. This switch has the following ports:

  • 48 100M/1/10/25-Gigabit Ethernet SFP28 ports (ports 1-48).

  • 6 10/25/40/50/100-Gigabit QSFP28 ports (ports 49-54)

  • One management port (one 10/100/1000BASE-T port)

  • One console port (RS-232)

  • 1 USB port

This switch includes the following user-replaceable components:

  • Fan modules (four) with the following airflow choices:

    • Port-side exhaust fan module with blue coloring (NXA-FAN-35CFM-PE)

    • Port-side intake fan module with burgundy coloring (NXA-FAN-35CFM-PI)

      Cisco Nexus 93180YC-FX3 ACI-Mode Switch Hardware Installation Guide - Overview [Cisco Nexus 9000 Series Switches] (1)

      Note

      Table 1. Fan Speeds for This Switch

      Port-Side Intake

      Fan Speed %

      Port-Side Exhaust

      Fan Speed %

      Typical/Minimum

      50%

      70%

      Maximum

      100%

      100%

    Cisco Nexus 93180YC-FX3 ACI-Mode Switch Hardware Installation Guide - Overview [Cisco Nexus 9000 Series Switches] (2)

    Note

    This switch runs with +1 redundancy mode, so that if one fan fails, the switch can sustain operation. But if a 2nd fan fails, this switch is not designed to sustain operation. Hence before waiting for major threshold temperature to be hit, the switch will power down due to Powered-down due to fan policy trigger.

    Cisco Nexus 93180YC-FX3 ACI-Mode Switch Hardware Installation Guide - Overview [Cisco Nexus 9000 Series Switches] (3)

    Note

    Each fan module has two rotors. The switch can function normally if one rotor inside the any one fan module fails. In case of more than one rotor failure, the switch will issue a warning and power down in 2 minute.

  • Power supply modules (two—One for operations and one for redundancy [1+1]) with the following choices:

    Cisco Nexus 93180YC-FX3 ACI-Mode Switch Hardware Installation Guide - Overview [Cisco Nexus 9000 Series Switches] (4)

    Note

    All fan modules and power supplies must use the same airflow direction.

    Cisco Nexus 93180YC-FX3 ACI-Mode Switch Hardware Installation Guide - Overview [Cisco Nexus 9000 Series Switches] (5)

    Note

    This switch may present access issues if installed between switches with greater chassis depth. Please consider this before installation.

Deployment Scheme for SFP-10G-T-X Transceivers

The following figure shows the maximum configuration density of SFP-10G-T-X SFP+ transceivers for this switch.

Cisco Nexus 93180YC-FX3 ACI-Mode Switch Hardware Installation Guide - Overview [Cisco Nexus 9000 Series Switches] (6)
Cisco Nexus 93180YC-FX3 ACI-Mode Switch Hardware Installation Guide - Overview [Cisco Nexus 9000 Series Switches] (7)

Active Port deploying the SFP+ 10GBASE-T transceiver, with max power consumption up to 2.5W.

Once configured with “media-type 10g-tx” in NX-OS or “Link Level Policy -> Physical Media Type -> SFP 10G TX” in ACI, these ports can deploy SFP-10G-T-X. Without such configuration, they behave like normal ports.

Cisco Nexus 93180YC-FX3 ACI-Mode Switch Hardware Installation Guide - Overview [Cisco Nexus 9000 Series Switches] (8)

Port Shutdown or Active with Passive Copper Cables only (Max. power consumption up to 0.1W).

Once 10g-tx is configured on yellow ports, ports to the left, right, top and bottom of the yellow port are referenced as blue ports. These adjacent ports will then support only low power Passive Copper DAC cable, or these can be left empty to conserve power. If 10g-tx configuration is removed from adjacent yellow ports, the blue ports will revert to behaving like normal ports.

Cisco Nexus 93180YC-FX3 ACI-Mode Switch Hardware Installation Guide - Overview [Cisco Nexus 9000 Series Switches] (9)

Active Port deploying any Cisco 1/10/25G optics (SFP, SFP+, SFP28) EXCLUDING SFP+ 10GBASE-T, with max power consumption up to 1.5W. These ports are not part of any scheme and can deploy all regular Cisco optics and behave like normal ports.

The following figure shows the switch features on the port side of the chassis.

Cisco Nexus 93180YC-FX3 ACI-Mode Switch Hardware Installation Guide - Overview [Cisco Nexus 9000 Series Switches] (10)

1

1PPS and 10MHz SMB ports

4

48 100M/1/10/25-Gigabit Ethernet SFP28 ports

2

GPS/GNSS antenna connector

5

6 10/25/40/50/100-Gigabit QSFP28 ports

3

LEDs

Cisco Nexus 93180YC-FX3 ACI-Mode Switch Hardware Installation Guide - Overview [Cisco Nexus 9000 Series Switches] (11)

Note

Time of Day, and PTP GM is not supported

To determine which transceivers, adapters, and cables are support this switch, see the Cisco Transceiver Modules Compatibility Information document.

The following figure shows the switch features on the power supply side of the chassis.

Cisco Nexus 93180YC-FX3 ACI-Mode Switch Hardware Installation Guide - Overview [Cisco Nexus 9000 Series Switches] (12)

1

Power supply modules (1 or 2) (AC power supplies shown) with slots numbered 1 (left) and 2 (right)

4

Management port (RJ45)

2

Fan modules (4) with slots numbered from 1 (left) to 4 (right)

5

USB port

3

Console port

6

ToD port

Table 2. ToD/1PPS RS422 Interface-RJ-45 Pinout

Pin

Signal_name

Description

1

NC

No Connect

2

NC

No Connect

3

1PPS_N

1PPS RS422

4

GND

-

5

GND

-

6

1PPS_P

1PPS RS422

7

TOD_N

Time of Day (ToD) RS422

8

TOD_P

Time of Day (ToD) RS422

The following figure shows the side of the chassis.

Cisco Nexus 93180YC-FX3 ACI-Mode Switch Hardware Installation Guide - Overview [Cisco Nexus 9000 Series Switches] (13)

1

Screw holes for mounting brackets

3

Grounding pad

Depending on whether you plan to position the ports in a hot or cold aisle, you can order the fan and power supply modules with port-side intake or port-side exhaust airflow. For port-side intake airflow, the fan and power supplies have burgundy coloring. For port-side exhaust airflow, the fan and power supplies have blue coloring.

The fan and power supply modules are field replaceable. You can replace one fan module or one power supply module during operations so long as the other modules are installed and operating. If you have only one power supply installed, you can install the replacement power supply in the open slot before removing the original power supply.

Cisco Nexus 93180YC-FX3 ACI-Mode Switch Hardware Installation Guide - Overview [Cisco Nexus 9000 Series Switches] (14)

Note

All fan and power supply modules must have the same direction of airflow. Otherwise, the switch can overheat and shut down.

Cisco Nexus 93180YC-FX3 ACI-Mode Switch Hardware Installation Guide - Overview [Cisco Nexus 9000 Series Switches] (15)

Caution

If the switch has port-side intake airflow (burgundy coloring for fan modules), you must locate the ports in the cold aisle. If the switch has port-side exhaust airflow (blue coloring for fan modules), you must locate the ports in the hot aisle. If you locate the air intake in a hot aisle, the switch can overheat and shut down.

Cisco Nexus 93180YC-FX3 ACI-Mode Switch Hardware Installation Guide - Overview [Cisco Nexus 9000 Series Switches] (2024)
Top Articles
Latest Posts
Article information

Author: Laurine Ryan

Last Updated:

Views: 5855

Rating: 4.7 / 5 (57 voted)

Reviews: 88% of readers found this page helpful

Author information

Name: Laurine Ryan

Birthday: 1994-12-23

Address: Suite 751 871 Lissette Throughway, West Kittie, NH 41603

Phone: +2366831109631

Job: Sales Producer

Hobby: Creative writing, Motor sports, Do it yourself, Skateboarding, Coffee roasting, Calligraphy, Stand-up comedy

Introduction: My name is Laurine Ryan, I am a adorable, fair, graceful, spotless, gorgeous, homely, cooperative person who loves writing and wants to share my knowledge and understanding with you.